(作者:王金帆[|]质管 刊发时间:2021-02)(查看:3733 下载:0) | (作者:Ki-Hyuk Park, MD, Jade S. Hiramoto, MD, Linda M. Reilly, MD, Matthew Sweet, MD[|]Jounal of vascula 刊发时间:2009-09)(查看:12888 下载:14) | 概述:Purpose: To describe variations in the shape, orientation, and length of the branches of multi-branched thoracoabdominal stent grafts.
Method: The branches were constructed in situ by attaching a covered stent (Fluency Plus Tracheobronchial Stent Graft; Bard Peripheral Vascular, Tempe, Ariz) to each of four caudally-oriented cuffs on custom-made stent grafts. Pre- and postoperative computed tomography (CT) scans of 38 consecutively treated patients were analyzed using a three- |
|
(作者:Steve Xydas, MD,a Benjamin Wei, MD,b Hiroo Takayama, MD,b Mark Russo, MD,b[|]Journal of thoracic and 刊发时间:2010-01)(查看:11633 下载:79) | 概述:Objective: Total aortic arch replacement typically requires hypothermic circulatory arrest, carrying risks of ce- rebral ischemia. We recently introduced left carotid–subclavian bypass before total aortic arch replacement with thoracic stent grafting to achieve hybrid arch reconstruction with short periods of selective antegrade cerebral per- fusion.
Methods: From 2004 to 2009, 332 patients underwent ascending aorta or arch replacements. Of these, 37 under- went total aortic arch replacement |
| (作者:Vikram Iyer, MD,Mark Rigby, MD, and George Vrabec Sr, MD[|]Jounal of vascular surgery 刊发时间:2009-08)(查看:11182 下载:5) | 概述:Acute aortic dissection is rarely seen in the patient with a previously repaired abdominal aortic aneurysm (AAA). There are few reports of this in the literature after open aneurysmec- tomy,1,2 and to our knowledge, only one report after endo- vascular AAA repair (EVAR).3 Retrograde dissection was thought to be the cause in this latter case, and this has also been reported after angioplasty or stenting of the thoracic and abdominal aortas, renal arteries, and iliac arteries.4-9
We report |
|
(作者:Wilson Y. Szeto, MD, William G. Moser, CRNP, Nimesh D. Desai, MD, Rita K. Milewski, MD[|]Annual of t 刊发时间:2009-06)(查看:8594 下载:84) | 概述:We report a case of a patient with a history of previous coronary artery bypass grafting undergoing endovascular aortic repair of a large pseudoaneurysm in the ascending aorta. Due to the limitations of the current technology, the endograft was deployed through a left ventricular transapical approach by using a left mini-thoracotomy |
| (作者:Naomichi Uchida *, Hidenori Shibamura, Akira Katayama, Norimitsu Shimada, Miwa Sutoh[|] 刊发时间:2008-11)(查看:6984 下载:7) | 概述:Objective: To describe the fate of the false lumen remaining in the descending thoracic aorta after extensive primary repair of the thoracic aorta by the modified elephant trunk technique with a stent graft for acute type A aortic dissection, particularly the changes of the false lumen on enhanced CT scanning. Methods: The subjects were 65 consecutive patients who received arch replacement with an open stent graft for type A acute aortic dissection. CT scanning was performed at 1, 3, 12, |
|
(作者:Satoshi Kawaguchi, MD, Yoshihiko Yokoi, MD, Taro Shimazaki, MD, Kenji Koide, MD, Masataka Matsu 刊发时间:2008-11)(查看:6445 下载:74) | 概述:Objectives: In the West, stent grafts for endovascular repair of thoracic aortic aneurysms have been commercially available for several years, whereas in Japan, a manufactured stent graft was not approved for this application until March 2008. Nevertheless, endovascular thoracic intervention began to be performed in Japan in the early 1990s, with homemade devices used in most cases. Many researchers have continued to develop homemade devices. We have participated in joint design and assess |
| (作者:David Rigberg, MD, Allan Tulloch, MD,Youngjae Chun, MS,Kotekar Panduranga Mohanchandra, PhD[|] 刊发时间:2009-08)(查看:6204 下载:5) | 概述:Objective: Although technological improvements continue to advance the designs of aortic stent grafts, miniaturization of the required delivery systems would allow their application to be available to a wider range of patients and potentially decrease the access difficulties that are encountered. We performed this feasibility study to determine if thin-film NiTi (Nitinol) could be used as a covering for stent grafts ranging from 16 mm to 40 mm in diameter. Specifically, we wished to dete |
|