文献分类
文献总数:299
综合评论
General Comments(4)
胸主动脉病变
Thoracic aortic pathologies(73)
腹主动脉病变
Abdominal Aortic Pathologies(37)
髂动脉病变
Iliac Aortic Pathologies(35)
多发病变
Multiple Pathologies(17)
影像学研究
Imaging Research(13)
血流动力学研究
Hemodynamic Research(5)
器材研究
Device Research(36)
分支型支架
Branched Stent Graft(62)
支架释放系统
Delivery System(1)
开放介入型支架
Open Endovascular Stent Graft(0)
法律法规
Laws & Regulations(1)
 
 
Results of Endografting of the Aortic Ar..
图片(0)查看(3236)下载(10)
Open-Branched Stent Graft Placement Make..
图片(3)查看(3054)下载(3)
Physiologic coarctation of the aorta re..
图片(6)查看(3005)下载(1)
Have hybrid procedures replaced open ao..
图片(2)查看(2964)下载(0)
Endovascular Repair of Thoracoabdominal..
图片(10)查看(3233)下载(12)
Secondary elephant trunk fixation wit..
图片(1)查看(3052)下载(2)
A Novel Endovascular Technique for Exclu..
图片(1)查看(2982)下载(3)
Observations on the Failure of Stent-gra..
图片(4)查看(2930)下载(4)
Supra-aortic Transposition for Combined ..
图片(0)查看(3169)下载(2)
Chuter Branched Stent-Grafts for Endovas..
图片(2)查看(3026)下载(4)
Complete Replacement of the Supraaortic ..
图片(1)查看(2971)下载(1)
Fenestration of Aortic Stent Grafts—In ..
图片(6)查看(2900)下载(19)
 
 
(作者:G. Melissano,*[|]European Journal of Vascular and Endovascular Surgery 刊发时间:2007-05)(查看:3236 下载:10)
概述:Endovascular approach to the aortic arch is an appealing solution for selected patients. Aim of this study is to compare the technical and clinical success recorded in the different anatomical settings of endografting for aortic arch disease.
(作者:Edward G. Soltesz, MD, MPH, and Roy K. Greenberg, MD[|] 刊发时间:2010-04)(查看:3233 下载:12)
概述:The standard surgical approach to thoracoabdominal an- eurysms is considerably demanding, and outcomes cor- relate with the number and severity of associated comorbidi- ties.1 Many large studies have reported mortality rates ranging from 7% to 17%. Cardiac, neurologic, respiratory, and renal complications limit the number of patients who are eligible for open surgery. Recent advances in operative tech- nique and use of adjunctive measures for spinal cord protec- tion have decreased, but
(作者:Roman Gottardi,Martin Funovics,Nella Eggers,Alexan[|]Journal of thoracic and cardiovascular surgery 刊发时间:2008-06)(查看:3169 下载:2)
概述:Background. Supra-aortic transpositions in various extents followed by endovascular stent graft placement are now an established tool in the treatment of various pathologies affecting the aortic arch. Results remain to be determined.
(作者:Liang-Wan Chen, MD, Xiao-Fu Dai, MD, Guo-Feng Yang, MD, Gui-Can Zhang, MD,[|]Annual of thoracic su 刊发时间:2010-07)(查看:3054 下载:3)
概述:In total arch replacement for acute type A aortic dissec- tion, the left subclavian artery anastomosis and the distal anastomosis at the descending aorta are often remarkably difficult because of the deep surgical field. We developed a single-branched stent graft that was constructed by adding a side arm stent-graft to a conventional aortic stent graft. By its open placement into the origin of the left subclavian artery and the descending aorta, the left subclavian artery anastomosis
(作者:Hitoshi Matsuda, Yoshihiko Tsuji, Koji Sugimoto, Yutaka Okita[|]European Journal of Cardio-Thoracic 刊发时间:2005-04)(查看:3052 下载:2)
概述:Four patients who underwent secondary elephant trunk fixation by endovascular stent grafting are presented and the advantage of this method to treat multiple/extensive thoracic aortic aneurysm is discussed. In two of them, the elephant trunk installation has been performed at another hospital for extensive aortic aneurysm. In two other patients, the aortic arch replacement and the elephant trunk installation were performed through median sternotomy, initially for multiple aortic lesio
(作者:Timothy A.M. Chuter, DM[|] 刊发时间:1900-01)(查看:3026 下载:4)
概述:
(作者:Michael R. Go, MD, Michael P. Siegenthaler, MD, Robert Y. Rhee, MD[|]Journal of vascular surgery 刊发时间:2008-10)(查看:3005 下载:1)
概述:Graft collapse is a known complication of thoracic aortic stent grafting, particularly in cases of traumatic thoracic aortic transection, when a typically smaller diameter aorta is repaired with a relatively large diameter device. In contrast, obstruction of the aorta from a stent graft that protrudes into the aortic arch but does not collapse is a less common complication of thoracic aortic stent grafting that can present as a functional aortic coarctation. We describe here two
(作者:V.M. Bhamidipaty,K. Sieunarine[|]European Journal of Vascular and Endovascular Surgery 刊发时间:2008-10)(查看:2982 下载:3)
概述:We present a case of a 78-year-old gentleman who was found to have a large saccular aneurysm of the inner aortic arch after complaining of change in the character of his voice. This lesion was successfully excluded using purely fenestrated endovascular techniques without compromising the origins of supra-aortic vessels. A novel technique with modification of fenestrated design was used to ensure accurate placement of the custom-made endograft. This technique has not been published before.
(作者:Thierry P. Carrel,Friedrich S. Eckstein,Jurg Schmi[|]Annual of thoracic surgery 刊发时间:2005-05)(查看:2971 下载:1)
概述:A 33-year-old female with Marfan syndrome presented in 1996 with acute peripartal aortic dissection. A composite graft was performed and intestinal resection had to be performed a few days later because of malperfusion-related ischemia. Recovery of the mother and the child was uneventful. In 2000, complete thoracoabdominal replacement was necessary because of expanding aneurysm Crawford type II, but the aortic arch was normal sized. The proximal anastomosis was performed at the level of the left
(作者:Rita Karianna Milewski, MD, PhD, Wilson Y. Szeto, MD, Alberto Pochettino, MD, G. William Moser, CRNP 刊发时间:2010-02)(查看:2964 下载:0)
概述:Objective: Open total arch procedures have been associated with significant morbidity and mortality in patients with multiple comorbidities. Aortic arch debranching with endovascular graft placement, the hybrid arch proce- dure, has emerged as a surgical option in this patient population. This study evaluates the outcomes of a contem- porary comparative series from one institution of open total arch and hybrid arch procedures for extensive aortic arch pathology. Methods: From July 2000 to Ma
(作者:R.J. Hinchliffe,[|] 刊发时间:2007-10)(查看:2930 下载:4)
概述:The results of endovascular stent-grafts in the abdominal aorta and descending thoracic aorta have been encouraging. Expanding the use of thoracic stent-grafts in to the aortic arch has been associated with increasing numbers of complications. Recently isolated cases of stent-graft collapse have been reported.
(作者:Petri Saari, MD, and Hannu Manninen, MD, PhD[|]Journal of vascular and interventional radiolody 刊发时间:2010-09)(查看:2900 下载:19)
概述:ABSTRACT Purpose: To evaluate the response of various stent grafts after needle fenestration and sequential dilation with standard percutaneous transluminal angioplasty (PTA) and cutting balloons and sealing of the fenestration with a side branch stent graft. Materials and Methods: Five commercially available aortic stent grafts (Endurant, Gore TAG, Talent, Valiant, and Zenith) were fenestrated with a needle. The fenestrations were sequentially dilated up to 10 mm with PTA balloons or cutt
 
第 3/ 6页
3
首页   |    联系我们   |   加入我们    |    关于我们   |   友情链接    |   网站地图   |   企业邮箱